Viessmann Boiler: Free-standing boiler stand

Updated · by Aurora Star Tech Inc.

Free-standing boiler stand on a Viessmann boiler: The boiler stand is for free-standing installation of one boiler. The wall location for the frame, bracket and vents must be calculated in the field, since no template is supplied.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Free-standing single boiler

How to fix free-standing boiler stand: step by step

  1. Fasten the stand securely to the floor using concrete expansion anchors, Hilti KB-TZ or equivalent.
  2. Attach the wall mounting bracket to the mounting frame with the supplied hardware.
  3. Check the wall bracket is level.
  4. Move the frame into position and secure it to the floor, and to the wall if needed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199

Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 installation instructions, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.