Viessmann Boiler: Frame mounting the boiler on the wall bracket
Frame mounting the boiler on the wall bracket on a Viessmann boiler: Steps to mount the boiler to the bracket and frame and level it before connecting piping.
Applies to: Vitodens 200-W B2HA 80 to 100, 285 to 352
How to fix frame mounting the boiler on the wall bracket: step by step
- Remove the external accessories connection box cover.
- Loosen the screws at the bottom of the boiler. Do not remove them fully.
- Remove the front enclosure panel by lifting it up and pulling it away from the boiler.
- Mount the boiler onto the mounting bracket and make sure it is secure. Install the holding bracket to the frame on top of the boiler.
- Adjust the levelling screws until the boiler is level.
- Connect the boiler to the installation fittings.
- Level the boiler both vertically and horizontally so condensate drains properly.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 200-W B2HA 80 to 100, 285 to 352 Installation Instructions, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.