External demand on a Viessmann boiler: External contact requests heat and can enforce a minimum boiler water temperature.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA 80 to 100

How to fix external demand: step by step

  1. Wire the floating contact to DE1, DE2 or DE3.
  2. Set the input to 3A:2, 3B:2 or 3C:2.
  3. Set pump response with 3F (internal pump), D7 (heating circuit pump) and 5F (DHW circulation pump).
  4. Set the minimum set boiler water temperature with 9B.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199

Source: Vitodens 200-W B2HA Service Instructions, p. 90. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.