Updated · by Aurora Star Tech Inc.

Enter coding level 1 and select a coding group on a Viessmann boiler: Opens the coding menu on the Vitotronic control to change installer settings.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA 80-100 Vitotronic 200-H

How to fix enter coding level 1 and select a coding group: step by step

  1. Press OK and the second button shown in the manual together for about 4 seconds.
  2. Select Coding level 1.
  3. Select the group: General, Boiler, DHW, Solar, Heating circuit 1/2/3, or All codes std device. The Solar group only appears when an SM1 solar control module is connected.
  4. Select the coding address.
  5. Select the value and confirm with OK.
  6. To reset all level 1 codes, choose Standard setting in Coding level 1. This also resets level 2 codes.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 200-W B2HA service instructions, p. 43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.