Viessmann Boiler: Connect CombiPLUS cables to the boiler power pump module
Connect CombiPLUS cables to the boiler power pump module on a Viessmann boiler: Wiring of the control cable Q and pump cable R inside the power pump module.
Applies to: Vitodens 100-W WB1B with CombiPLUS
How to fix connect combiplus cables to the boiler power pump module: step by step
- Route control cable Q through the fourth hole of the power pump module base and pump cable R through the second hole. Secure both with the locknuts.
- Connect pump cable wire BK1 (neutral) to the power pump neutral on terminal block X3.
- Connect pump cable wire BK2 (line) to the power pump line on terminal block X3.
- Connect the green/yellow ground wire to any open terminal on terminal block X2.
- Plug the DHW temperature sensor / flow sensor (5-pin) into plug-in X7.
- Plug the diverter valve (6-pin) into plug-in X10.
- Fit the supplied anchors behind the cables, fix the conduit clip with its screw, and press cables Q and R into the clip.
- Check the wiring diagram for additional wiring details and the CombiPLUS connections on page 29.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W, WB1B CombiPlus Installation & Service Instructions, p. 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.