Viessmann Boiler: Combustion analysis and heating circuit leak check
Combustion analysis and heating circuit leak check on a Viessmann boiler: Required before and after work on gas appliances.
Applies to: Vitodens 200-W B2HB 19 to 125
How to fix combustion analysis and heating circuit leak check: step by step
- Take a CO2 measurement before and after working on the gas appliance.
- Record combustion values in the order given in the Maintenance Record (page 102).
- Check heating and domestic hot water connections and fittings, pumps and valves for leaks and correct any found.
- Perform a gas leak test after reinstalling gas connections; use soap solution, never flame.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB service instructions, p. 20, 22-23. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.