Viessmann Boiler: Coastal or marine installation
Coastal or marine installation on a Viessmann boiler: Salt spray and humidity corrode the exposed metal casing and fan housing in damp marine areas.
Applies to: Boilers near damp or salty marine environments
Common causes of coastal or marine installation
- Chloride from sea spray combined with high relative humidity.
How to fix coastal or marine installation: step by step
- Do not use a direct vent system that draws outdoor air in these locations.
- Install the boiler with a room air dependent vent system so it draws indoor air with lower humidity.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 installation instructions, p. 9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.