Viessmann Boiler: Clean condensate siphon (P-trap)

Updated · by Aurora Star Tech Inc.

Clean condensate siphon (P-trap) on a Viessmann boiler: Keep the condensate siphon clear so condensate drains freely.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W, WB1B

Common causes of clean condensate siphon (p-trap)

  • Blocked siphon
  • Condensate not draining freely

How to fix clean condensate siphon (p-trap): step by step

  1. Check the siphon for unimpeded drainage.
  2. Remove all hoses from the siphon.
  3. Release the locking tabs underneath and lift the siphon out.
  4. Clean the siphon and reinstall it.
  5. Refit all hoses and secure the drain hose with cable ties.
  6. Fill the siphon by pouring 0.3 L (10 fl. oz.) of water into the combustion chamber.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Viessmann Vitodens 100-W, WB1B installation and service instructions, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.