Viessmann Boiler: Check the neutralization unit
Check the neutralization unit on a Viessmann boiler: Checks condensate acidity and granulate level.
Applies to: Vitodens 200-W B2HA 19, 28, 35
How to fix check the neutralization unit: step by step
- Check condensate pH with a field-supplied pH strip.
- If pH is below 6.5, replace the granulate.
- If contaminated, rinse the neutralization unit with tap water.
- Refill the granulate up to the mark. The red marking is the minimum fill level.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 200-W B2HA service instructions, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.