Viessmann Boiler: Check fuses on the control unit and external accessories box
Check fuses on the control unit and external accessories box on a Viessmann boiler: Use this to check the control unit fuse and the fuses in the external accessories connection box.
Applies to: Vitodens 200-W B2HB
How to fix check fuses on the control unit and external accessories box: step by step
- Switch off the power.
- Release the side latches and pivot the control unit down.
- Remove cover A.
- Check fuse F1 (see wiring diagram on p. 92).
- To check the accessories box, switch off the power and open the external accessories connection box.
- Check fuses F1 and F2 in that box (see wiring diagram on p. 92).
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Viessmann Vitodens 200-W B2HB service instructions, p. 83. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.