Settings shortcuts: Boiler tips (part 7 of 10)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on settings shortcuts for boiler. Check each one against the manual for your exact model before acting.

Room-dependent control for small or low-energy homes

Viessmann · Vitocrossal 300 CU3A small or low-energy buildings

For apartments under 860 ft2 (80 m2) or low energy houses, room-dependent control gives faster response.

  1. Install the Vitotrol 200A or 300A room control with the boiler.
  2. Use room-dependent control rather than outdoor reset alone for these buildings.

Rotary address dial: leave at 0

Viessmann · Versatronik 501 and 501D gateways

The rotary dial gives an address for installations that use several gateways. For a normal installation it is not adjusted and stays at the factory default of 0.

  1. Check that the rotary dial reads 0.
  2. Only change it when the installation uses several gateways and an address is required.

Select boiler sequence (300-K only)

Viessmann · Vitotronic 300-K cascade control

Cascade sequence can be changed. The control offers several sequences based on the set parameters and internal calculations.

  1. Open the extended menu.
  2. Select "Boiler sequence".
  3. Set the required sequence and confirm with OK.

Select display language

Viessmann · Display language

Sets the language shown on the Vitocontrol-S display.

  1. Open the hinged cover on the programming unit.
  2. Press the heating circuit selector button until it lights up.
  3. Press the participant number button; 'Participant No.' shows.
  4. Press up or down until the required language shows.
  5. Confirm; the display returns to the boiler temperature.
  6. Close the hinged cover.

Select language (300-K only)

Viessmann · Vitotronic 300-K

Sets the menu language on the 300-K control.

  1. Open the extended menu.
  2. Select "Settings", then "Language".
  3. Select the required language.

Select the heating circuit before any setting or scan

Viessmann · Vitocontrol-S, VD2/CT3/CM2 with 2 or 3 heating circuits

On systems with two or three heating circuits, pick the right circuit first. Each circuit has its own selector button. On single-circuit systems you can start settings straight away. If you skip this step, the display asks you to select button 1, 2 or 3.

  1. Press the selector button for the heating circuit you want (1 = system circuit, 2 or 3 = circuit with mixing valve).
  2. Confirm the button lights up and shows the current heating program.
  3. Make your setting or scan now. The lights go out after a short time if you make no further input.

Select the heating circuit before changing central heating settings

Viessmann · Vitotronic 300-K (type MW2B) with several heating circuits

In systems with several heating circuits, select the circuit first. Factory names are HC1, HC2 and HC3, and custom names replace them. Selection is not possible in single-circuit systems.

  1. Open the extended menu.
  2. Select Heating.
  3. Select the required heating circuit.

Select the heating circuit before every setting or scan

Viessmann · Vitocontrol-S with two or three heating circuits

On systems with two or three heating circuits, select the correct circuit first. The selected circuit's button lights up along with its current program and any party or energy saving mode. If you skip this, the display asks you to select button 1, 2 or 3. With one circuit, settings can be made straight away.

  1. Press heating circuit button 1 (system circuit), 2 (circuit with mixing valve) or 3 (circuit with mixing valve).
  2. Check that the selected circuit button and its program lights are on.
  3. Make your setting or scan.
  4. If the display asks you to select a circuit, select it before continuing.

Select the heating program

Viessmann · Vitotrol 200A remote control

Chooses between winter mode, summer mode and frost protection standby. The current program symbol flashes while you change it.

  1. Press the heating program key. The symbol for the current program flashes.
  2. Press the program key again until the symbol for the required program flashes.
  3. Press OK to confirm.

Select the heating program when the burner or heating is not running

Viessmann · Single-boiler and multi-boiler systems

Program 9 is the setting that stops the burner. Program rw or w is the normal running choice (page 6 of the manual).

  1. If the program 9 button is lit, set the rw or w heating program.
  2. Use rw as the setting for multi-boiler systems when the burner does not switch on.

Select the language

Viessmann · Control

Language is chosen from the Settings menu.

  1. Press Menu, then Settings, then Language.
  2. Select the required language and press OK.

Select the operating mode (summer or winter)

Viessmann · Vitotrol 300 remote control

Pick the mode that fits the season. The indicator light comes on and the chosen mode shows briefly in the display. Space heating and DHW mode: heating follows the heating cycle, DHW follows the DHW cycle, and frost protection stays on. DHW only mode: no space heating, DHW and DHW recirculation pump follow their cycle, frost protection stays on. Shut-off mode: no space heating and no DHW, frost protection stays on. Without a DHW tank the display shows 'Without Function' when this key is pressed. All recirculation pumps run every 24 hours to prevent seizing.

  1. Press the operating mode button for the mode you want.
  2. Check that the indicator light is on and the mode name appears briefly.

Select the operating program for a heating circuit

Viessmann · System and lead boiler section 1

Choose the operating program for each heating circuit. Make this change only at the system and lead boiler section 1.

  1. From the home screen, tap Menu, then Heating, then the required heating circuit.
  2. Tap Operating program.
  3. Select the program, for example Heating and DHW, DHW only or Standby mode.
  4. Tap OK to confirm.

Selecting a heating circuit

Viessmann · Multi-circuit systems

Heating circuits are factory named HC1, HC2 and HC3. The contractor may have renamed them at the Vitotronic, and that name then shows in place of HC. Selection is only available when more than one circuit is controlled. Returning to the standard menu sets the header back to HC1.

  1. Open the extended menu.
  2. Select the required heating circuit.
  3. Make the central heating changes for that circuit.

Selecting a heating circuit for central heating settings

Viessmann · Multi-circuit systems

On systems with more than one heating circuit, pick the circuit before changing its central heating settings. The selection is not offered when only one circuit is controlled.

  1. Open the extended menu.
  2. Select the settings you want to change.
  3. Select the required heating circuit.
  4. Make the central heating changes for that circuit.

Selecting the heating circuit

Viessmann · Vitotronic 300-K, systems with several heating circuits

Systems with several heating circuits need the circuit chosen before any central heating setting is changed. Circuits are factory labelled HC1, HC2 and HC3. If renamed, the custom name appears instead of the default label.

  1. Open the extended menu.
  2. Select Heating.
  3. Select the required heating circuit.

Set a DHW time phase

Viessmann · Vitotronic 200 and 300-K DHW time program

Sets start and end times for DHW heating in the extended menu. Set the start and end time for each phase. To cancel a phase mid-setting, keep pressing the back key until the required screen appears.

  1. Open the extended menu.
  2. Select "DHW", then "DHW circ time prog" or the DHW time program.
  3. Select "Individual".
  4. Select the part of the week or the single day.
  5. Select the time phase.
  6. Set the start and end time for that phase.
  7. Press the exit key to leave the menu.

Set a heating circuit's room temperature levels

Viessmann · Multi-circuit systems

Select the heating circuit first when the system has several. Then change the reduced, standard or comfort level and confirm.

  1. On the Heating circuit or Continuous operation default display, select the heating circuit if needed.
  2. Select the heating circuit in the menu bar if the screen shows it.
  3. Set the value for Reduced, Standard or Comfort.
  4. Confirm.

Set a holiday program

Viessmann · Vitocrossal 300 CA3B with Vitotronic 300 GW6C

Sets departure and return dates for the holiday program, which applies to all heating circuits. It starts at 00:00 on the day after departure and ends at 00:00 on the return date, so the time program runs on both those days. Contact the heating contractor before changing it. Effect: in Heating and DHW circuits, rooms drop to the reduced temperature. In DHW only circuits, central heating stays off with frost protection for the boiler and DHW tank. DHW heating stops, with frost protection for the DHW tank.

  1. From the home screen, open Menu, then Heating.
  2. Select the heating circuit.
  3. Open Holiday program.
  4. Enter the departure date and the return date.
  5. Tap OK to confirm.

Set a time program for central heating

Viessmann · System and lead boiler section 1

Time phases divide the day into blocks. Up to 4 time phases per day can be set, and each day of the week can differ. Settings apply to room heating, DHW heating and the DHW recirculation pump. Make these changes only at the system and lead boiler section 1.

  1. From the home screen, tap Menu, then Heating, then Heating circuit 1.
  2. Tap Time program heating, then tap the day (for example Mo), then tap Edit.
  3. Set the start and end points for time phase 1, then for time phase 2.
  4. Tap OK to confirm.

Set altitude for high-elevation installs

Viessmann · Vitodens 200-W B2HA 80-100, 285-352

The boiler is factory set for altitudes up to 5,000 ft (1,500 m). For higher sites, change the altitude using coding address 93 in coding level 2 (General).

  1. Confirm the site altitude.
  2. Enter coding level 2 (General).
  3. Set coding address 93 to suit the altitude.

Set date and time

Viessmann · Date and time

Time and date are preset at the factory. Manual reset is not needed when a radio clock receiver accessory is fitted.

  1. Open the hinged cover on the programming unit.
  2. Press the time button; 'Time' shows. Adjust with up or down, then confirm.
  3. The display shows 'Date'. Adjust with up or down, then confirm.
  4. The display returns to the boiler temperature.
  5. Close the hinged cover.

Set DHW temperature

Viessmann · Vitotronic 300-K

DHW temperature is set in the DHW menu. The factory value is not shown on these pages.

  1. Open the extended menu and select DHW.
  2. Select Set DHW temperature.
  3. Set the required value.

Set display backlighting

Viessmann · Control display

Brightness can be set separately for standby and for control operation.

  1. Press Menu, then Settings, then Screen.
  2. Choose Brightness standby or Brightness control.
  3. Set the required value and press OK to confirm.

Set display brightness (operation and standby)

Viessmann · Control panel

Separate brightness values are set for operation and for standby.

  1. Open Settings, then 'Display setting'.
  2. Select 'Brightness, operation' or 'Brightness, standby'.
  3. Select the required value.
  4. Confirm.

Set display contrast (300-K only)

Viessmann · Vitotronic 300-K

Adjusts the display contrast of the 300-K control.

  1. Open the extended menu.
  2. Select "Settings", then "Contrast".
  3. Set the required contrast.

Set display language

Viessmann · Control panel

Selects the language used on the control screen.

  1. Open Settings.
  2. Select 'Language'.
  3. Select the required language.
  4. Confirm.

Set display units

Viessmann · Control panel

All units can be changed, for example temperature (°C or °F) and date format.

  1. Open Settings.
  2. Select 'Units'.
  3. Select the unit type, e.g. °C for temperature.
  4. Confirm.

Set heating time cycles

Viessmann · Vitotronic 300 Model GW2

Sets the start and finish times of up to 4 heating cycles, either identical for all days or per day of the week.

  1. Open the hinged cover on the programming unit.
  2. Press the heating circuit selector button so it lights up.
  3. Press the heating time program button; 'Htg. Time Program' appears.
  4. Use the up or down button to select '1-7' for all days, or a single day such as 'Mo'.
  5. Press OK to confirm; cycle 1 appears.
  6. Press OK, then set the cycle start time with the up or down button and confirm.
  7. Set the cycle finish time with the up or down button and confirm.
  8. Repeat for cycles 2 to 4; to skip a cycle, press the skip button.
  9. Close the hinged cover.

Set holiday mode on Lago FB

Viessmann · Lago FB remote control

Holiday mode starts at once and sets the room temperature to 15C/59F for 24 hours.

  1. Set the mode dial to HO.
  2. Use the value dial to set the number of days.
  3. The mode ends on the last day at 24:00.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.