Settings shortcuts: Boiler tips (part 6 of 10)
Short, practical technician tips on settings shortcuts for boiler. Check each one against the manual for your exact model before acting.
Minimum boiler temperature protection can be enabled or disabled
Viessmann · Vitotronic 100 KW10B
The minimum boiler temperature and freeze-up protection is controlled by the electronic boiler temperature sensor and can be turned on or off with a DIP switch.
Moving the programming unit to the top of the boiler
Viessmann · Vitodens 100-W B1HE and B1KE
By default the programming unit sits on the underside of the boiler. For easier access it can be moved to the top. Do not change the cable routing or its fixing point on the casing, since incorrect routing causes heat damage and EMC problems.
- Remove the hinges and keep them for reinstallation.
- Pull in the tabs to release the control housing.
- Pull the control housing forward out of the jacketing.
- Disconnect the plug of the connecting cable from the bracket.
- Rotate the control housing 180 degrees.
- Reconnect the plug on the right-hand side.
- Reinstall the control housing into the jacket.
- Install the clips into the openings at the bottom of the front cover.
Name heating circuits
Viessmann · Heating circuits
Each heating circuit can be named individually, for example 'Ground floor' (1 to 20 characters). The 1, 2, 3, 4 abbreviations stay in the default display. The name appears in the main menu.
- Open Settings.
- Select 'Rename heating circuits'.
- Select the heating circuit.
- Type the name.
- Confirm.
Name heating circuits and choose the standard-menu circuit
Viessmann · Vitocrossal 300 CU3A
Heating circuits can be renamed, but the abbreviations HC1, HC2 and HC3 stay. Each name can be up to the number of characters the display allows. The standard menu can show HC1, HC2 or HC3.
- Open the extended menu.
- Select 'Settings'.
- Select 'Name for heating circ.' and choose the circuit.
- Select 'Change?' and enter the name, then press OK.
- To pick the circuit for the standard menu, select 'Standard menu' and choose the circuit.
Name heating zones
Viessmann · Heating zones
Each heating zone can be named individually (1 to 20 characters). The name appears in the main menu.
- Open Settings.
- Select 'Rename heating zone'.
- Tap the required heating zone.
- Type the name.
- Confirm.
Name the heating circuits
Viessmann · Heating circuits 1 to 3
Each heating circuit can have its own name, up to 32 characters. The name shows in the main menu.
- Press Menu, then Settings, then Name for heating circuit.
- Select the heating circuit and enter the name.
- Press OK to confirm.
Name the heating circuits (300-K only)
Viessmann · Vitotronic 300-K
Heating circuits 1, 2 and 3 can get custom names. The HC1, HC2 and HC3 abbreviations stay in place. Entering a blank name is not covered; reset returns the default "Heating circuit" name.
- Open the extended menu.
- Select "Settings", then "Name for heating circ.".
- Select the heating circuit (1, 2 or 3).
- Select "Change?".
- Choose each character, moving to the next with the arrow.
- Press OK to save all characters and exit.
- To return to the default name, select "Reset?".
Name the heating circuits (Vitotronic 300-K)
Viessmann · Vitotronic 300-K MW1B
Gives heating circuits HC1, HC2 and HC3 a custom name. The HC abbreviations stay on the display. The default name for HC1 is shown as Ground floor in the example.
- Open the extended menu.
- Select Settings, then Name for heating circ.
- Select Heating circuit 1, 2 or 3, then Change?.
- Choose each character with the selector keys; the next key moves to the next character.
- Press OK to accept all characters and leave the menu.
- To clear a name, use Reset?; the default name for that circuit returns.
Navigating the Expert Area settings
Viessmann · Versatronik 200 Expert Area
Use the F buttons to move through the Expert Area. Exit each level with the Cancel button.
- Select the parameter and press F [OK] to activate it for editing.
- Set the value and press F [OK] to save.
- Use F [==>] to select the boiler number when entering boiler sequences.
- Press F [Cancel] to exit the current level.
Normal and reduced room temperature
Viessmann · Vitocontrol-S VD2/CT3/CM2
Set separately for each heating circuit. Changing room temperature also changes the start/stop points of the heating circuit pump when pump logic is active.
- Normal day temperature: turn the set value adjuster to the required value. It is applied automatically after about 2 seconds.
- Reduced night temperature: press the tm button to call it up.
- Change the value with the up or down button.
- Confirm with the button shown.
One-time DHW heating outside the time program
Viessmann · DHW heating
At least one heating circuit must not be in Standby mode. Party mode is used to force DHW heating once. Turn Party mode off afterwards so central heating does not run at standard temperature by accident.
- Make sure at least one heating circuit is not in Standby mode.
- Open the extended menu and select Heating.
- Select the heating circuit if needed.
- Select Party mode.
- Set Party mode to OFF after the DHW heating is done.
Open the main menu
Viessmann · Vitotronic 300 GW6C service display
The main menu holds all scans and settings. The menu overview is on page 35 of the manual.
- If the screensaver is on, tap the display, then tap Menu.
- From anywhere in the menu, tap the menu button in the footer, then tap Menu.
Open the standard menu and the extended menu
Viessmann · Vitodens 200-W B2HB programming unit
The standard menu is for common settings. The extended menu holds less-used functions such as time programs and holiday programs. If the screen saver is on, the first key press wakes the display. The screen saver turns on after a few minutes without changes and dims the display.
- If the screen saver is active, press any key except the ? key to wake the display.
- To reach the standard menu from elsewhere in the menu, keep pressing until it appears.
- To open the extended menu from the screen saver, press any key except ?, then press the menu key.
- To open the extended menu from elsewhere in the menu, press the menu key.
Open the time and date menu
Viessmann · Versatronik 200 controller display
Use the main menu to reach the time, date and holiday settings.
- Press the Home button to show the Main Menu.
- Turn the rotary dial until Time-Date is shown on the screen.
- Press the key beside User to select the menu option.
- Select the menu item you need: Time, Date, Holiday start, Holiday end, Start summer time or End summer time.
- Press Cancel to leave the current screen.
Open the time program view from the main menu
Viessmann · Versatronik 200 controller display
Use the main menu to reach the heating circuit timer information.
- Press the Home button to show the Main Menu.
- Turn the rotary dial until Time Program is shown on the screen.
- Press the key beside User to select the menu option.
- Pick the heating circuit to view its timer information.
- Press Cancel to leave the current screen.
Operating mode selection
Viessmann · Vitotronic 300 operating unit
The program selector buttons choose the operating mode. Freeze-up protection stays active in all modes.
- Select heating and domestic hot water for full operation.
- Select domestic hot water only to heat only the DHW tank.
- Select standby to shut down normal heating while keeping freeze-up protection.
Operating programs for central heating and DHW
Viessmann · Vitocrossal 200 CI2 central heating and DHW
Central heating has two operating programs: Heating (follows room or supply target and time program) and Standby mode (no central heating, boiler frost protection active). DHW has ON (heated per DHW temperature and time program) and OFF (no DHW heating, tank frost protection active). External hook-up means an external device such as an EM-EA1 changed the program, and it cannot be changed at the control unit while that is active.
- Select Heating for normal central heating operation.
- Select Standby mode to stop central heating for the relevant heating circuit while keeping frost protection.
- Set DHW to ON or OFF as needed.
- If External hook-up shows, change the operating program at the external device instead.
Operating programs for summer and absence
Viessmann · Vitotronic 300 GW6C control on Vitocrossal 300 CA3B
The operating program selects heating and hot water behaviour. DHW only keeps hot water running with heating off. Standby stops heating and hot water for long periods. Economy mode lowers room temperature for short absences. Holiday program reduces room temperature and turns off DHW.
- Select DHW only for summer, when only hot water is needed.
- Select Standby mode when no heating or hot water is needed for long periods.
- Select Economy mode for short absences.
- Select the Holiday program when away for a longer time.
Outdoor reset slope and shift adjustment
Viessmann · Application 4 weather-compensated ZC1
Slope and shift set the heating curve. Adjusting either one changes the displayed curve.
- Use the arrow keys to move from slope to shift.
- Adjust slope or shift and check the graphed curve change before leaving the screen.
Party mode (DHW or central heating outside the time program)
Viessmann · Vitocrossal 300 CU3A
Party mode gives heating outside the normal time program. Set it to OFF again afterwards so central heating does not keep running at standard room temperature. The manual says at least one system heating circuit must be set to 'Heating and DHW' or 'Only DHW' for this to work. The first step to switch Party mode on is missing from the manual text.
- Open the extended menu.
- Select 'Heating'.
- Select 'Party mode'.
- Set 'Party mode' to OFF when the party is over.
Party mode for temporary heating and DHW
Viessmann · HK1S and HK3S
Party mode gives space heating and DHW for a short time outside the preset program. It is only available when set up with the party button.
- Open the hinged cover on the programming unit.
- Press the party button; the button lights and the party temperature flashes.
- Press up or down until the required party temperature shows.
- Confirm; the value stops flashing and is stored.
- Close the hinged cover.
Party mode: run heating or DHW briefly outside the schedule
Viessmann · Vitocontrol-S, VD2/CT3/CM2
Party mode runs central heating and DHW for a short time, outside the preset program. It holds a party temperature value.
- Open the hinged cover and select the heating circuit.
- Press the party mode key so the button lights and the party temperature flashes.
- Adjust the party temperature with up/down, then confirm.
- Close the cover.
- To cancel early, press the heating circuit selector and the party key again. The light stays on for about 1 minute and the mode stays active until then.
Quick heat-up and quick setback for mixing valve circuits
Viessmann · Mixing valve circuits with room temperature input
Room temperature influence can be boosted briefly. It acts only when the set room temperature changes by at least 2 °C / 3.6 °F.
- Quick heat-up: press the party button, or switch from reduced to normal heating, to raise the room set point by 2 °C / 3.6 °F or more.
- Quick setback: press the economy button, or switch from normal to reduced heating, to lower the room set point by 2 °C / 3.6 °F or more.
- Quick heat-up and setback stop when the set room temperature is reached.
- Use coding b6 for quick heat-up/setback and b2 for room temperature influence.
Quick heat-up, quick setback and economy functions
Viessmann · Heating circuits with room temperature input
Quick heat-up and quick setback change the room set point by at least 2 K (3.6 °F) until the set room temperature is reached. Economy functions switch the heating circuit pump off and drop the supply set point to 0 °C (32 °F).
- Quick heat-up: press the party button or change from reduced to normal heating mode.
- Quick setback: press the economy button or change from normal to reduced heating mode.
- Economy pump logic: set outdoor cut-off with coding A5.
- Extended economy: check outdoor cut-off A6, room set reduction A9, mixing valve economy A7 (12 minutes closed) and room limit b5.
Reading and changing the boiler sequence
Viessmann · Multi-boiler systems with Vitocontrol-S, VD2/CT3/CM2
The digits in the basic display show the boiler numbers in the current actual sequence. Hyphens show status: boilers before the first hyphen are activated, boilers between the hyphens are available but not needed, and boilers after the second hyphen are blocked (for example by a fault). The operator-requested sequence can differ from the actual sequence, because faults and the heating contractor's settings can change it. The sequence criteria are set by the heating contractor at start-up, and sometimes no alternative sequence is available.
- Open the hinged cover on the programming unit.
- Press the button combination to show the alternative operator-requested sequence (shown without hyphens); hold for about 2 seconds.
- Press the button(s) until the required boiler sequence appears.
- Press the confirm button; the display returns to the actual boiler sequence.
- Close the hinged cover.
Reduce maximum burner output
Viessmann · Vitocrossal 300 CA3B Dual Fuel 2.5 to 6.0
The maximum heating output of each burner can be set to 70 to 100% of rated output using the burner control unit.
- Hold button S for more than 2 seconds until the menu indicator blinks.
- Press button F until 6 shows under Service.
- Press button S. 6 shows under Status.
- Press button S. 1 shows under Status and the current maximum output (%) shows under Service.
- Press button F or D to choose the desired maximum output.
- Press button S to confirm. 1 under Service means success, 0 means it failed.
- Press button S to change the operating status indicator.
- Press button R. The system reboots.
Reduce operational input on burner control
Viessmann · Vitocrossal 200 CM2 burner control
Limit the maximum burner input between 0% (lower input) and 100% (upper input) if needed.
- Make sure the burner is in standby (Status 0, Service 0).
- Press button S and hold for more than 2 seconds until the display area flashes.
- Press button Y or E until 6 appears in the Service display.
- Press button S until 6 appears in the Status display.
- Press button S. A 1 appears in the Status display and the current max input (%) shows in the Service display.
- Press Y/E or B/G to set the required maximum input.
- Press S to confirm. A 1 shows on success; 0 means the adjustment failed.
- Press S to return to the operating display.
- Press button R for more than 2 seconds to restart and apply settings.
Reducing heat-up time after reduced mode
Viessmann · Heating circuit transition from reduced to standard
When switching from reduced to standard room temperature, the boiler water or supply temperature is raised for a set time to speed heat-up. Example in the manual: 50 °C plus 20% gives 60 °C for 60 minutes.
- Set the additional increase of the set boiler water or supply temperature at coding address FA.
- Set the duration of the raised temperature at coding address FB.
Reset all weekday DHW cycles to a single program
Viessmann · DHW time program
If different cycles were set per weekday and you want the same cycles every day again, use the reset from the '1-7' display. This also resets all time cycles to factory settings.
- With the display showing '1-7', press the confirm reset option as described in the manual.
- Note that all time cycles return to factory settings.
- Re-enter the required cycles if needed.
Return to the standard menu from the outdoor reset programming unit
Viessmann · Vitodens 200-W B2HA 80 to 100, 285 to 352
Use this to get back to the standard menu from the screen saver or from deeper inside the menu.
- If the screen saver is on, press any key except the help key.
- If you are somewhere in the menu, keep pressing the back key until the standard menu appears.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.