Other: Boiler tips (part 14 of 45)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for boiler. Check each one against the manual for your exact model before acting.

Disconnect power before servicing the boiler

Viessmann · Boiler junction box and all service work

Power inside the boiler junction box must be disconnected before any service work on the boiler.

  1. Disconnect power inside the boiler junction box before servicing the boiler.

Display backlight behavior

Viessmann · Vitotrol 300 remote control

The display light comes on when any button is pressed, provided the supplied batteries are installed. It turns off about 30 seconds after the last operation.

Display backlighting

Viessmann · Vitocrossal 300 CA3B

Sets the brightness of the screen and the screen saver.

  1. From the home screen, select Settings.
  2. Select Screen.
  3. Select Brightness screen saver or Brightness control.
  4. Set the required value.
  5. Confirm.

Display gas consumption

Viessmann · Control panel

Shows gas consumption under the General information group.

  1. Open Information.
  2. Confirm with OK.
  3. Select 'General'.
  4. Confirm with OK.

Display symbols

Viessmann · Vitodens 200-W B2HB 45, 57, 160, 199

Symbols appear depending on system version and operating state.

  1. 9 = standby with frost protection monitoring.
  2. w = DHW only.
  3. wz = heating and DHW.
  4. e = frost protection monitoring.
  5. s = central heating at standard temperature.
  6. m = central heating at reduced temperature.
  7. Party mode, Economy mode, solar circuit pump running and burner in operation each have their own symbol.
  8. Service message and fault message symbols show on the display.

Display symbols and messages

Viessmann · Vitodens 200-W B2HA 112/150/399/530

Symbols show only when the system version and operating state call for them. They cover heating program, circuit state, pumps, solar, burner status, party and economy modes, and service or fault messages.

  1. Heating program symbols: standby with frost protection monitoring, DHW only, heating and DHW.
  2. Circuit symbols: frost protection monitoring, central heating with standard temperature, central heating with reduced temperature.
  3. Burner in operation: the burner symbol is shown.
  4. Zone circuit display: shows zone pump output, outdoor temperature (weather compensated only), set zone temperature, and burner modulation rate in %.
  5. Service message and fault message are shown in the display header.

Display symbols for heating programs and operating states

Viessmann · Vitodens 200-W B2HB control unit display

Heating program symbols: 9 means standby with frost protection monitoring, w means DHW only, wz means heating and DHW. Operating symbols: e means frost protection monitoring is active, s means central heating at standard temperature, m means central heating at reduced temperature. Other symbols show party mode, economy mode, solar circuit pump running, burner in operation, a service message, or a fault message. Not all symbols show on every system; they depend on system version and operating state.

Display symbols on the control unit

Viessmann · Vitotronic control unit display

Symbols do not always show; they depend on the system version and operating state. Heating program symbols: standby with frost protection, DHW only, heating and DHW, frost protection monitoring, central heating at standard or reduced temperature. Other symbols: party mode, economy mode, solar circuit pump running, burner in operation, service message, fault message. HC1/HC2/HC3 show the heating circuit and ZC1/ZC2/ZC3 show the zone circuit selected in the standard menu.

Display symbols on the programming unit

Viessmann · Vitodens 222-F, B2TB 19, 35, 68, 125

Symbols appear depending on system version and operating state. Heating program symbols: 9 standby with frost protection, w DHW only, wz heating and DHW. Other symbols: e frost protection monitoring, s central heating at standard temperature, m central heating at reduced temperature. Party mode and economy mode have their own symbols, as do service and fault messages. Zone circuit (ZC 1-3) and heating circuit (HC1-3) symbols show which circuit is selected in the standard menu.

Display symbols on the Vitocontrol-S

Viessmann · Vitocontrol-S, VD2/CT3/CM2

Symbols show heating and DHW status. They appear only when the system type and operating state call for them.

  1. Read the symbols: e = risk of freezing; s = central heating at normal room temperature; m = central heating at reduced room temperature; w = DHW heating, DHW pump on; p = heating circuit pump on; U = fault message; V = mixing valve open; v = mixing valve closed.
  2. If a U fault symbol shows, check the fault and correction tables in the manual for the cause.

Display symbols reference

Viessmann · Programming unit display

Symbols appear depending on system version and operating state. Heating circuit labels show HC1, HC2 or HC3.

  1. Heating program symbols: standby with frost protection monitoring; DHW only; heating and DHW.
  2. Frost protection monitoring shown with a separate symbol.
  3. Central heating with standard temperature and central heating with reduced temperature each have a symbol.
  4. Party mode and economy mode each have a symbol.
  5. Solar circuit pump running and burner in operation each have a symbol.
  6. Service message and fault message each have a symbol.

Display symbols that appear only when needed

Viessmann · Vitotronic 200-H HK1S and HK3S

Some symbols are not shown all the time. They appear according to system type and operating status: risk of freezing, normal or reduced room temperature heating, DHW heating with DHW pump on, heating circuit pump on, and mixing valve open or closed.

Display symbols to check during service

Viessmann · Vitotronic 200-H HK1M

Flashing symbols mean a value can be changed. The U symbol shows a fault. The r symbol shows space heating is active, rp shows the heating circuit pump is running, and s and m show normal or reduced room temperature. Some symbols only appear depending on system version and operating state.

Displaying active and acknowledged faults

Viessmann · Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0

An active fault makes the red fault display flash and show the symbol with Fault. If several faults are present, a list appears and the faults are shown in red in time order.

  1. Look at the red fault display on the control unit.
  2. If several faults are active, open the Faults list to see them in time order.
  3. Use the fault code tables to find the cause and the measures.

Disposal of the control unit battery

Viessmann · Vitocontrol-S VD2/CT3/CM2

The control unit contains a built-in non-toxic battery.

  1. Have a competent person remove the battery.
  2. Dispose of the spent battery at an appropriate collection point.

Do not adjust Multi-boiler system menu item

Viessmann · Vitodens 200-W B2HB 45, 57, 160, 199

Changing the Multi-boiler system item turns a weather-compensated control unit into a constant temperature control unit. Do not adjust it.

  1. Leave the Multi-boiler system menu item unchanged.

Do not adjust the multi-boiler system menu item

Viessmann · Vitodens 222-F B2TB

The multi-boiler system item turns a weather-compensated control unit into a constant temperature control unit.

  1. Leave the 'Multi-boiler system' menu item unchanged unless the system design calls for it.

Do not adjust the valve seat gas pressure switch GDW2

Viessmann · GDW2 valve seat gas pressure monitoring switch

GDW2 is factory set to 10 mbar (4 in. w.c.) and must be left alone. Its activation causes E1 or E2 faults on the burner control.

Do not bend or kink capillaries

Viessmann · Vitocontrol-S CM2 capillary sensors

Warning: damaged capillaries cause control malfunction.

  1. Do not bend or kink the capillaries when routing them to the sensor well.

Do not change Multi-boiler system menu item

Viessmann · Vitodens 200-W B2HA 112/150/399/530

The 'Multi-boiler system' item turns a weather-compensated control unit into a constant temperature control unit. Do not adjust it during normal service.

Do not change the Multi-boiler system menu item

Viessmann · Vitodens 200-W B2HA 80 to 100, 285 to 352

Changing this item turns a weather-compensated control unit into a constant temperature control unit. Leave it alone unless that is the intent.

Do not connect the boiler 41-plug directly to the burner when venting is installed

Viessmann · Vitotronic 200 KW2 with venting system

If a venting system is installed, the 41-plug from the boiler control must not go straight to the burner.

  1. Connect the 7-pole plug to the wall vent system counter plug.
  2. See the technical instructions of the vent system.

Do not mix vent systems

Viessmann · All vent materials

Mixing pipe, fittings or joining methods from different vent manufacturers is not permitted.

  1. Use one vent manufacturer's pipe, fittings and joining method throughout.
  2. Follow the manufacturer's sidewall termination kit instructions.

Do not operate a boiler that has been under water

Viessmann · Vitotronic 300-K MW2C boiler system

A boiler that was submerged must not be used. The control system and any gas control that was under water must be replaced.

  1. Do not use the boiler.
  2. Call a qualified heating contractor to inspect the boiler.
  3. Replace any control system part and gas control that was under water.

Do not reroute the Switching Module-V terminals

Viessmann · Vitotronic 200 KW2 with Switching Module-V

The terminal assignment on the Switching Module-V is fixed and must not be changed.

  1. Keep the Switching Module-V wiring to the printed terminal assignment.

Do not run the boiler in contaminated combustion air

Viessmann · Vitodens 200-W B2HA 19, 28, 35

Dust, lint or chemical vapours damage the boiler and can cause carbon monoxide and property damage. Chemicals stored in the boiler room also produce poisonous by-products.

  1. Check the area for dust, lint or chemicals before start-up. These are common in construction sites, garages, workshops, dry cleaning or laundry areas, near pools and in manufacturing facilities.
  2. Do not operate the boiler if combustion air is contaminated. Relocate or correct the source first.
  3. Have the boiler inspected and serviced by a qualified heating contractor at least once a year.

Do not run the control without the junction box lid

Viessmann · Vitodens 100-W B1HE/B1KE

The junction box lid separates mains and extra low voltage and seals the control enclosure off from the air box. It must be fitted when replacing the control unit or closing the enclosure.

Do not run without the front cover

Viessmann · All Vitodens 200-W B2HB models

Never operate the boiler with the front cover removed.

  1. Put the front cover back on before the boiler is run.

Do not share the condensate drain

Viessmann · Vitocrossal 300 CU3A 26 to 199

Other appliance drains must not feed the boiler condensate line.

  1. Do not connect the drain from any other appliance, such as a water softener backwash, to the condensate drain pipe.

Do not use a damaged gas control or boiler that was under water

Viessmann · Vitodens 200-W B2HA 45, 60

If any part was under water, do not run the appliance. Have a qualified service technician inspect it and replace the water-damaged control system and gas control parts. Never use tools on the gas control knob.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.