Viessmann Boiler: Vent pipe installation

Updated · by Aurora Star Tech Inc.

Vent pipe installation on a Viessmann boiler: Use approved vent material only. Keep the run short with few elbows. Support horizontal runs so they do not sag, and keep them as short as possible.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitorond 100 VR1 oil-fired boilers

How to fix vent pipe installation: step by step

  1. Route the vent for the shortest path with minimum elbows.
  2. Fit the factory vent adaptor to the flue gas collar with three equally spaced corrosion-resistant self-tapping screws and high-temperature silicone, or equivalent.
  3. Connect the chimney through an 18 in (457 mm) field-supplied, slightly inclined intermediate section.
  4. Pitch horizontal runs up at least 1/4 in per ft from the boiler to the terminal.
  5. Support horizontal runs with metal strap every 4 ft (1.2 m).
  6. Seal all flue joints.
  7. Insulate any uninsulated vent pipe to reduce flue gas cooling and noise.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitorond 100 VR1 installation and service instructions, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.