Viessmann Boiler: System Layout 4: radiator circuit plus underfloor mixing circuit
System Layout 4: radiator circuit plus underfloor mixing circuit on a Viessmann boiler: Vitodens 200-W B2HB with DHW, one direct radiator circuit and one underfloor circuit with 3-way mixing valve.
Applies to: Vitodens 200-W B2HB
How to fix system layout 4: radiator circuit plus underfloor mixing circuit: step by step
- Make sure radiator circuit output flow is at least 30% greater than the underfloor circuit flow.
- Keep the total flow of both circuits below the boiler maximum on page 31.
- Use a low-loss header if flow exceeds page 31 values or is unknown (strongly recommended).
- Install the accessory kit for a heating circuit with mixing valve.
- Pipe the DHW circulating pump P into the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Installation Instructions, p. 36. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.