Viessmann Boiler: System Layout 2: radiator circuit with low-loss header and DHW
System Layout 2: radiator circuit with low-loss header and DHW on a Viessmann boiler: Vitodens 200-W B2HB with one heating circuit and a low-loss header, plus DHW. Used when heating circuit flow is above the boiler maximum water flow.
Applies to: Vitodens 200-W B2HB
How to fix system layout 2: radiator circuit with low-loss header and dhw: step by step
- Install a low-loss header; it is strongly recommended if flow exceeds page 31 values or is unknown.
- Install the boiler pump 20 and heating circuit pump 28/20 (coding address 53).
- Fit the Viessmann temperature sensor for the low-loss header.
- Note the expansion tank location as shown.
- Pipe the DHW circulating pump F into the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Installation Instructions, p. 34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.