Updated · by Aurora Star Tech Inc.

Rooms cold while the burner is running on a Viessmann boiler: The burner runs but the rooms stay cold, even with a low outdoor temperature.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Room heating

Common causes of rooms cold while the burner is running

  • Time incorrectly set
  • Heating program w or 9 selected
  • DHW priority active on a tank system
  • On/off switch on the mixing valve motor is OFF
  • Heating curve setting incorrect
  • Control unit incorrectly programmed

How to fix rooms cold while the burner is running: step by step

  1. Set the correct time on page 20.
  2. Set heating program rw (page 6) if program w or 9 is selected.
  3. On tank systems, wait until the DHW tank heats up (w goes off in the display).
  4. Turn the mixing valve motor on/off switch to I ON.
  5. Check and correct the heating curve on page 21.
  6. Check and correct the temperature settings (page 8), time program (page 12) and heating program (page 7).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitotronic 300 GW2 operating instructions, p. 29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.