Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Mount the oil burner on the boiler

Updated · by Aurora Star Tech Inc.

Mount the oil burner on the boiler on a Viessmann boiler: Fit the burner to the combustion chamber door using the factory flange, spacer bolts and gasket. Set the burner tube insertion as the burner manufacturer specifies.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitorond 100 VR1 22-33, 91-140 oil boiler with Riello, Beckett or Carlin burner

How to fix mount the oil burner on the boiler: step by step

  1. Unpack the burner. The mounting flange is already fitted at the factory.
  2. Fit the four M8 spacer bolts into the threaded holes of the combustion chamber door.
  3. Slide the burner gasket over the spacer bolts.
  4. Mount the burner.
  5. Fasten the burner with the M8 nuts and washers supplied.
  6. Set the burner tube insertion using the calibration chart (page 38 of the manual, not on these pages) and the burner maker's instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitorond 100, VR1 Installation and Service Instructions, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair