Viessmann Boiler: Lighting and operating procedure
Lighting and operating procedure on a Viessmann boiler: The appliance has no pilot. It uses an electronic ignition that lights the burner automatically.
Applies to: Vitodens 222-F, B2TB
How to fix lighting and operating procedure: step by step
- Set the thermostat or operating control to its lowest setting.
- Turn off all electric power to the appliance.
- Close the main gas shut-off valve.
- Wait five minutes to clear any gas, then smell for gas near the floor. If gas is smelled, stop and follow the gas odor response.
- Open the main gas shut-off valve.
- Turn on electric power to the appliance.
- Set the thermostat or operating control to the desired setting.
- If the appliance will not operate, turn off the gas to the appliance and call the service technician or gas supplier.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125
Source: Vitodens 222-F, B2TB installation manual, p. 59. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.