Viessmann Boiler: Install the safety header
Install the safety header on a Viessmann boiler: Build the safety header with the pressure relief valve, low water cutoff, automatic air vent and temperature/pressure gauge on the boiler outlet.
Applies to: All Vitocrossal 300 CA3B Dual Fuel models
How to fix install the safety header: step by step
- Fit the hex bushing and the air vent with shut-off base.
- Install the pressure relief valve rated 75 psi, or an alternate valve matched to the operating pressure.
- Install the low water cutoff and the temperature/pressure gauge.
- Use the reducer and nipple sized for the model from the connection table.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitocrossal 300 CA3B Dual Fuel installation manual, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.