Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Inspect and replace burner mesh assembly and refractory

Updated · by Aurora Star Tech Inc.

Inspect and replace burner mesh assembly and refractory on a Viessmann boiler: Replace the burner mesh assembly if the wire mesh is damaged.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocrossal 300 CU3A burner head

Common causes of inspect and replace burner mesh assembly and refractory

  • Damaged wire mesh
  • Damaged refractory

How to fix inspect and replace burner mesh assembly and refractory: step by step

  1. Remove electrodes A.
  2. Remove the four nuts D and take off the fan with gas valve C.
  3. Remove the three nuts B and take off the burner mesh assembly H.
  4. Remove refractory F with thermal insulating mat E.
  5. Remove old burner mesh gasket G.
  6. Check refractory F and replace if damaged.
  7. Fit thermal insulating mat E and refractory F per electrode position, using the positioning aid.
  8. Fit new burner mesh assembly H with new gasket G and secure with three nuts.
  9. Fit the fan with gas valve.
  10. Do not damage the burner head wire gauze.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199

Source: Viessmann Vitocrossal 300 CU3A 26 to 199 Service Instructions, p. 23. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977