Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Fixed high limit test #2 (flow switch jumpered)

Updated · by Aurora Star Tech Inc.

Fixed high limit test #2 (flow switch jumpered) on a Viessmann boiler: Alternative test that trips the fixed high limit with the boiler valve closed and the flow switch jumpered. Only do this with the boiler monitored and under control.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HB 45, 57, 160, 199

How to fix fixed high limit test #2 (flow switch jumpered): step by step

  1. Close the boiler valve and jumper across the flow switch.
  2. Run the boiler at high fire. For B2TB models, set coding address 06 to maximum to hold high fire.
  3. Let the temperature keep rising until the fixed high limit trips.
  4. Slowly open the boiler valve to cool the boiler down.
  5. Remove the jumper and restore normal operation.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199

Source: Viessmann Vitodens 200-W B2HB 45, 57, 160, 199 service instructions, p. 8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977