Updated · by Aurora Star Tech Inc.

Fill condensate trap with water on a Viessmann boiler: Fill the condensate trap before start-up so flue gases cannot pass through the drain. Close the main gas supply before removing the front panel.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HB 45, 57, 160, 199

How to fix fill condensate trap with water: step by step

  1. Close the main gas supply valve.
  2. Remove the accessories connection box cover.
  3. Loosen the bottom screws (do not remove them completely) and slide out the front enclosure panel.
  4. Remove retaining clip A from condensate trap B.
  5. Disconnect condensate trap B and fill it with water.
  6. Reinstall condensate trap B and secure with retaining clip A.
  7. Reinstall the front enclosure panel and keep the front cover on before operating the boiler.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199

Source: Viessmann Vitodens 200-W B2HB 45, 57, 160, 199 service instructions, p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977