Viessmann Boiler: Field wiring to digital inputs and low-voltage outputs
Field wiring to digital inputs and low-voltage outputs on a Viessmann boiler: Keep the separation required for external contacts and the 0-10 V input.
Applies to: EA1 extension module and external connections
How to fix field wiring to digital inputs and low-voltage outputs: step by step
- For external contacts, observe safety category II: 8.0 mm air gap and creep path, or 2.0 mm insulation thickness against live parts.
- Ensure DC separation between the LV output and the earth conductor of the on-site voltage source when using the 0-10 V input.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H HK1B installation and service instructions, p. 77. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.