Viessmann Boiler: External demand via plug aVH

Updated · by Aurora Star Tech Inc.

External demand via plug aVH on a Viessmann boiler: A floating contact on plug aVH switches the burner on based on load.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Boilers with plug aVH

How to fix external demand via plug avh: step by step

  1. Connect the floating contact to terminals "2" and "3" on plug aVH.
  2. When the contact closes, the burner switches on based on load.
  3. The boiler water temperature is limited by the preset maximum boiler water temperature or by the mechanical adjustable high limit.
  4. Set the required boiler set-point via coding address "9b".
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitotronic 300 GW2 installation and service instructions, p. 39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.