Viessmann Boiler: External control: switch on 2nd stage burner
External control: switch on 2nd stage burner on a Viessmann boiler: Dry contact at plug aVD starts the second burner stage.
Applies to: Two-stage burner
How to fix external control: switch on 2nd stage burner: step by step
- Connect a dry contact to terminals 2 and 3 of plug aVD.
- Contact closed: both burner stages run.
- Contact open: both stages stop.
- 2nd stage switches off 2 K sooner than the 1st stage.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitotronic 100, GC1 installation manual, p. 60. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.