Viessmann Boiler: Do not use Teflon tape or compression fittings on oil lines
Do not use Teflon tape or compression fittings on oil lines on a Viessmann boiler: Teflon tape can cause oil valves to fail. Compression fittings are not allowed on the oil piping. Use non-hardening pipe joint compound on all threads.
Applies to: Oil piping at the burner and fuel unit
If the unit shows an error code, look it up: Viessmann Boiler codes
More commissioning tips for boiler
Source: Vitorond 100, VR1 Installation and Service Instructions, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.