Viessmann Boiler: DHW piping size and flow for tank applications

Updated · by Aurora Star Tech Inc.

DHW piping size and flow for tank applications on a Viessmann boiler: DHW supply and return piping must be sized so the field pump has enough head to push water through the tank coil and the boiler heat exchanger. Undersized piping can cause short-cycling and poor DHW supply.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocrossal 300 CU3A with DHW storage tank

How to fix dhw piping size and flow for tank applications: step by step

  1. Use at least 1¼ in. pipe between the boiler DHW connections and the Viessmann DHW tank connections.
  2. With a non-Viessmann tank, calculate the tank coil pressure drop against the field pump's residual head.
  3. Confirm enough flow reaches the boiler heat exchanger.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

2635455794125160199CU3ACU3A 26CU3A 35CU3A 45CU3A 57CU3A 94CU3A 125CU3A 160CU3A 199Vitocrossal 300, type CT3

More commissioning tips for boiler

Source: Viessmann Vitocrossal 300 CU3A installation manual, p. 43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.