Updated · by Aurora Star Tech Inc.

Connect low water cut-off device (VD2/VD2A/CT3) on a Viessmann boiler: Wire the external LWCO into the control terminals. The factory jumper between 12 and 15 must come out first.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: VD2, VD2A and CT3 controls

How to fix connect low water cut-off device (vd2/vd2a/ct3): step by step

  1. Disconnect power before working on the wiring.
  2. Remove the jumper between terminals 12 and 15.
  3. Connect the LWCO as shown in the diagram.
  4. Use the power supply for accessories (aBH) and the external equipment connection (aBÖ) as labelled.
  5. Refer to the LWCO device manual for interconnection details.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

GC1KW10B

Source: Vitotronic 100 GC1 installation and service instructions, p. 73. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.