Updated · by Aurora Star Tech Inc.

Close the combustion chamber door after service on a Viessmann boiler: Reassemble the chamber and make sure the door seals.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: VR1 40 to 63, 161 to 245

How to fix close the combustion chamber door after service: step by step

  1. Put the flue gas turbulators back in.
  2. Refit the combustion chamber insert if one was removed.
  3. Close the combustion chamber door and tighten the two bolts evenly.
  4. Install the front panel.
  5. Fasten the burner hood if fitted and lock it in place.
  6. Reconnect the oil burner and follow the burner installation and start-up manual.
  7. Confirm no tools are left inside the combustion chamber.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitorond 100 installation and service manual, p. 49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.