Viessmann Boiler: Checking the plate heat exchanger
Checking the plate heat exchanger on a Viessmann boiler: Drain the boiler on the heating water and DHW sides first. Small amounts of water may trickle out during removal.
Applies to: Vitodens 222-F B2TB
How to fix checking the plate heat exchanger: step by step
- Shut off and drain the boiler on the heating water and DHW sides.
- Release the side closures and pivot the control unit forward.
- Remove the siphon (see p. 25).
- Push insulating mat A upwards and remove it.
- Undo two screws B and pull plate heat exchanger C out to the front.
- Check the heating water and DHW connections for contamination and scaling. Replace the plate heat exchanger if required.
- Install in reverse order with new gaskets.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125
Source: Vitodens 222-F B2TB service instructions, p. 85. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.