Viessmann Boiler: Burner motor power supply, 240 VAC 1 PH
Burner motor power supply, 240 VAC 1 PH on a Viessmann boiler: For burners with 240 VAC single-phase supply and conduit connection. Fuse and wire sizing come from the burner manual.
Applies to: VD2/VD2A/CT3 controls, 240 VAC 1 PH burners
How to fix burner motor power supply, 240 vac 1 ph: step by step
- Disconnect power to the burner and the boiler control.
- Connect 240 VAC to terminals 21, 22 and 23 on the DIN rail in the connection enclosure.
- Provide a fuseable disconnect according to local codes.
- Connect the supplied power cable to the motor terminals on the burner.
- Connect the cable plug to the socket on the DIN rail in the connection enclosure.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 300 GW2 installation and service instructions, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.