Viessmann Boiler: Burner fault on first start-up (air in gas line)
Burner fault on first start-up (air in gas line) on a Viessmann boiler: Air in the gas supply pipe, especially with LPG, can cause a burner fault on initial start-up. Ignition is direct spark.
Applies to: Vitocrossal 300 CU3A initial start-up
How to fix burner fault on first start-up (air in gas line): step by step
- Wait about 5 seconds after the fault.
- Press the "R" button to reset the burner.
- The ignition sequence repeats automatically.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
More reset & cancel tips for boiler
Source: Viessmann Vitocrossal 300 CU3A 26 to 199 Service Instructions, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.