Viessmann Boiler: Burner does not switch on or only switches on erratically
Burner does not switch on or only switches on erratically on a Viessmann boiler: The burner does not light or cycles unpredictably.
Applies to: Burner ignition and fuel supply
Common causes of burner does not switch on or only switches on erratically
- Control unit incorrectly programmed or set
- Fault on control unit
- No fuel supply
How to fix burner does not switch on or only switches on erratically: step by step
- Check the heating program setting and the programming unit settings, and correct them if needed.
- If a control unit fault is suspected, consult the heating contractor. The boiler can then be run temporarily at constant boiler water temperature by turning override switch S to h, with the cover left open.
- Oil or LPG: check the fuel supply and reorder if needed.
- Natural gas: open the gas shut-off valve or contact the gas supplier.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 300 GW2 operating instructions, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.