Viessmann Boiler: Boiler does not start up

Updated · by Aurora Star Tech Inc.

Boiler does not start up on a Viessmann boiler: No burner start and no heat from the boiler.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 100, GC1 with Vitocontrol-S

Common causes of boiler does not start up

  • Heating system switch 8 is off
  • Electrical isolator switch, if installed, is off
  • Fuse in the domestic power circuit or control unit has blown or tripped
  • No heat request from the Vitocontrol-S

How to fix boiler does not start up: step by step

  1. Switch on the heating system switch 8.
  2. Switch on the electrical isolator switch if fitted.
  3. If a fuse has blown or tripped, inform the heating contractor.
  4. Check the heat request settings on the Vitocontrol-S.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitocontrol-S VD2/CT3/CM2 operating instructions, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.