Updated · by Aurora Star Tech Inc.

Acknowledging and recalling faults on a Viessmann boiler: A fault is acknowledged from the programming unit. The red fault light keeps flashing until the cause is fixed. An acknowledged fault that is not fixed within 24 hours shows up again on the display. Acknowledged faults can be recalled, and a fault from another LON unit shows as its participant number with EE for external fault.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 100 GC1 programming unit

How to fix acknowledging and recalling faults: step by step

  1. Press the acknowledge button to clear the displayed fault.
  2. To recall an acknowledged fault, press and hold the button for about 2 seconds.
  3. Use the up or down button to select the fault and view it.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

GC1KW10B

More reset & cancel tips for boiler

Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 100. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.