Viessmann Boiler: Access coding level 1
Access coding level 1 on a Viessmann boiler: Coding level 1 holds the basic system and boiler codings. Only addresses that fit the system type and equipment are shown.
Applies to: Vitotronic 300 GW2 coding level 1
How to fix access coding level 1: step by step
- Press 9 and w together for about 2 seconds to enter coding level 1.
- Use the up or down button to select the coding address, then press OK to confirm.
- Use the up or down button to change the value, then press OK to confirm.
- Press 9 and w together for about 1 second to leave coding level 1.
If the unit shows an error code, look it up: Viessmann Boiler codes
More access & passwords tips for boiler
Source: Vitotronic 300 GW2 installation and service instructions, p. 114. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.