Short, practical technician tips on settings shortcuts for water heater. Check each one against the manual for your exact model before acting.

Adjust tank temperature with Up and Down

Navien · NWP500-50, NWP500-65, NWP500-80

Press Up or Down while the temperature is flashing. The new value is stored once the display stops flashing. Settings are kept during a power outage.

  1. Close all hot water faucets first.
  2. Press Up or Down until the target temperature shows.
  3. Wait for the display to stop flashing to save.

Adjusting the water temperature

Navien · NR-21DU remote controller

Temperature changes in 1°F (0.5°C) steps. The setting is saved automatically after about 5 seconds with no button press. Temperatures above 125°F (52°C) can scald.

  1. Press the Up or Down button to change the set temperature.
  2. Wait 5 seconds without pressing a button so the setting is saved.
  3. Stay within the range for the water heater type shown in the temperature range table.

Change the tank temperature

Navien · NWP500 all operating modes

Adjust the set temperature with the Up and Down buttons. The setting is stored once the display stops flashing.

  1. Make sure all hot water faucets are closed.
  2. Press Up or Down until the desired temperature shows on the display.
  3. Wait until the display stops flashing to store the setting.

Changing the water temperature

Navien · NPN indoor and outdoor models

Close all hot water faucets and make sure the internal and any external circulator pumps are off before changing the setting. The new value is stored once the display stops flashing.

  1. Close all hot water faucets and confirm circulator pumps are off.
  2. Press the + (Up) or – (Down) button until the desired temperature shows on the display.
  3. Wait until the display stops flashing; the setting is then saved.

Front panel temperature buttons

Navien · Indoor models with front panel

The Up and Down buttons on the front panel change the hot water temperature.

  1. Press the Up button to increase the temperature.
  2. Press the Down button to decrease the temperature.
  3. Do not change the temperature while hot water is being used.

Open NPE-A2/S2 parameter settings

Navien · NPE-A2/S2 water heater with H2Air

Parameter changes are made from the installer menu on the NPE-A2/S2 water heater.

  1. Open the Installer Menu and select 2. Parameter Settings.
  2. Use the Up or Down button to move between parameters or change a value.
  3. Press OK to select a parameter or to confirm a change.

Set a recirculation timer schedule

Navien · NPN non-condensing water heaters only

Programs up to three recirculation reservation schedules. Times are set in 30 minute increments. Only available when NPN non-condensing water heaters are connected.

  1. Press the Timer button twice to open Reservation Schedule #1.
  2. Press Up or Down to set the recirculation start time, then press OK.
  3. Press Up or Down to set the stop time, then press OK to save.
  4. Repeat for Reservation Schedules #2 and #3 if needed.
  5. During a scheduled period the preheating icon turns on and the reservation area flashes.

Set the clock

Navien · NPN non-condensing water heaters only

Sets the controller time. Only available when NPN non-condensing water heaters are connected. Minutes are set first, then the hour.

  1. Press the Timer button for 2 seconds.
  2. Press Up or Down to set the minutes, then press OK.
  3. Press Up or Down to set the hour.
  4. Press OK to finish and save the time.

Setting the recirculation timer

Navien · NPN outdoor models; A models with preheating function for the reservation icon

Recirculation timer times are set in 30-minute steps. This only works when external circulating pumps are connected and on. Up to three reservation schedules can be set.

  1. While setting the clock, press the Preheat & Timer button to enter the recirculation timer (Reservation Schedule #1).
  2. Set the activation time with Up or Down, then press OK to set the deactivation time.
  3. Set the deactivation time with Up or Down, then press OK to save.
  4. Repeat for Reservation Schedules #2 and #3 if needed.

Turn Lock Mode on or off

Navien · NPE remote controller

Locks the front panel against accidental presses and child adjustment. With lock on, only the Lock button works, but errors can still be reset and settings can still be changed from the front panel.

  1. Press the Lock button for 2 seconds to turn Lock Mode on or off.
  2. Confirm the Lock icon shows on the display when active.

DHW operating program ON or OFF

Viessmann · DHW heating on/off

DHW ON: DHW is heated per the DHW temperature and time program. DHW OFF: no DHW heating, but tank frost protection stays active. Not valid for systems with a DHW tank thermostat (Aquastat-type).

  1. Call up the home screen.
  2. Select Turn on/off, then confirm with OK.
  3. Select DHW, then confirm twice with OK.
  4. Select ON or OFF, then confirm with OK.
  5. Acknowledge the information with OK.
  6. Press and hold the exit button for about 4 sec to leave the menu.

High temperature limit for high heating water supply

Viessmann · Vitocell 100-V CVWC

If the heating water supply runs above 248°F (120°C), install an approved high limit that caps the tank DHW temperature at 180°F (82°C).

  1. Confirm the heating water supply temperature.
  2. If it can exceed 248°F (120°C), install an approved high limit.
  3. Set the high limit so the tank DHW temperature does not exceed 180°F (82°C).

Set the DHW target temperature (Standard level)

Viessmann · DHW temperature setting

Not adjustable on systems with a DHW tank thermostat (Aquastat-type); the boiler maximum then applies. Do not set DHW below 122°F (50°C) for hygiene reasons. Hot water can cause serious injury.

  1. Call up the home screen.
  2. Select DHW, then confirm with OK.
  3. Select Temperature level, then confirm.
  4. Select Standard, then confirm.
  5. Set the target value and confirm with OK.
  6. Acknowledge the information with OK.
  7. Press and hold the exit button for about 4 sec to leave the menu.

Tempering valve for scald protection

Viessmann · Vitocell 100-V CVWC

A tempering valve is required when the DHW storage temperature exceeds 140°F (60°C) to protect against scalding. Follow local plumbing codes.

  1. Install a tempering valve on the DHW outlet if storage temperature will exceed 140°F (60°C).
  2. Check local plumbing code for additional requirements.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.