Viessmann Water Heater: Temperature and pressure relief (T&P) valve checks
Temperature and pressure relief (T&P) valve checks on a Viessmann water heater: The T&P valve must stay unobstructed and visible for discharge. Water leaking or discharging from it means unsafe temperature or pressure build-up is possible. Mineral build-up on the valve seat is possible.
Applies to: Vitocell 100-V CVWC
Common causes of temperature and pressure relief (t&p) valve checks
- Mineral build-up on the T&P valve seat
- Unsafe temperature or pressure build-up in the tank
How to fix temperature and pressure relief (t&p) valve checks: step by step
- Make sure there is no valve or restriction between the tank and the T&P valve, or between the T&P valve and the discharge outlet.
- Check that the discharge line slopes to allow unobstructed, visible flow toward a floor drain.
- If water is coming out of the discharge pipe, contact the heating contractor immediately.
- Operate the valve test lever at least once per year to confirm the waterways are clear.
- Have a licensed professional heating contractor reinspect the T&P valve at least once every three years.
- Report any dripping or discharge from the T&P valve to the heating contractor right away.
If the unit shows an error code, look it up: Viessmann Water Heater codes
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, p. 27. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.