Viessmann Water Heater: Install the G to NPT adaptors on the heating water connections
Install the G to NPT adaptors on the heating water connections on a Viessmann water heater: Two 1 in. G to 1 in. NPT adaptors go on the heating system supply and return. Each one uses the gasket supplied with it.
Applies to: All Vitocell 100-V CVWC sizes
How to fix install the g to npt adaptors on the heating water connections: step by step
- Place the gasket supplied with the adaptor on the adaptor.
- Thread the 1 in. G to 1 in. NPT adaptor into the heating supply or return connection. Do not overtighten, because this can damage the gasket.
- Use the wrench flats near the adaptor thread with the two-hand wrench method. Hold the adaptor with one wrench and tighten the fitting or pipe with the second.
- Repeat for the other adaptor.
If the unit shows an error code, look it up: Viessmann Water Heater codes
Source: Vitocell 100-V CVWC installation manual, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.