Viessmann Water Heater: Install the DHW tank temperature sensor

Updated · by Aurora Star Tech Inc.

Install the DHW tank temperature sensor on a Viessmann water heater: Sensor is mounted in the tank sensor well using the supplied mounting hardware.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocell 100-V CVWC DHW tank temperature sensor

How to fix install the dhw tank temperature sensor: step by step

  1. Carefully pull the sensor mounting hardware out of the tank sensor well.
  2. Mount the sensor on the outside of the sensor spring-clip, not in the center groove, so it is flush with the front of the clip.
  3. Push the sensor cabling into the groove of the mounting hardware.
  4. Push the sensor retainer with sensor into the sensor well as far as it will go.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Water Heater codes

Models

Vitocell 100-V CVWC 53 USG (200 L)Vitocell 100-V CVWC 66 USG (250 L)Vitocell 100-V CVWC 79 USG (300 L)

Source: Vitocell 100-V CVWC installation, service and operating instructions, p. 19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service