Viessmann Water Heater: Domestic water connections
Domestic water connections on a Viessmann water heater: Piping between boiler and tank with service-accessible connections and the required safety devices. Drawing is conceptual only; field piping must be verified by the heating contractor.
Applies to: Vitocell 100-V CVWC domestic hot water piping
How to fix domestic water connections: step by step
- Use detachable fittings for all pipe work.
- Pipe the boiler and tank together, using the factory supplied adaptors so connections are accessible for service.
- Seal unused connections with brass caps.
- Insulate the domestic hot water supply piping.
- Fit a recirculation pump, check valve and time switch on the DHW recirculation pipe, if used.
- Install the required isolation valves, drain valve, pressure reducing valve, water filter, backflow preventer and expansion tank where local code requires them.
- Install a field-supplied anti-scald tempering valve where DHW temperature may exceed local limits or 140°F (60°C).
If the unit shows an error code, look it up: Viessmann Water Heater codes
Models
Vitocell 100-V CVWC 53 USG (200 L)Vitocell 100-V CVWC 66 USG (250 L)Vitocell 100-V CVWC 79 USG (300 L)
Source: Vitocell 100-V CVWC installation, service and operating instructions, p. 22-23. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.