Viessmann Water Heater: DHW connection layout and relief valve installation
DHW connection layout and relief valve installation on a Viessmann water heater: Layout drawing for DHW piping. Piping must be field verified by the heating contractor. Key points: install the relief valve on each tank per code, fit shut-off valves, and use a precharged expansion tank wherever a backflow preventer is installed.
Applies to: Vitocell 100-V CVWC
How to fix dhw connection layout and relief valve installation: step by step
- Install the T&P relief valve on each tank in a way that meets local code.
- Fit shut-off valves on the DHW supply and cold water lines.
- Run a discharge pipe from the relief valve and a drain.
- Where a backflow preventer is installed, add a precharged expansion tank per local plumbing code.
- Fit a thermostatic mixing or anti-scald valve on the DHW outlet.
- Field verify the full piping arrangement, since the drawing is conceptual.
If the unit shows an error code, look it up: Viessmann Water Heater codes
Models
Vitocell 100-V CVWC 53 USG (200 L)Vitocell 100-V CVWC 66 USG (250 L)Vitocell 100-V CVWC 79 USG (300 L)
Source: Vitocell 100-V CVWC Technical Data Manual, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.