Updated · by Aurora Star Tech Inc.

How to read the D5CSRA cooling performance matrices on a Viessmann mini-split: Pages 64 to 72 hold cooling capacity matrices for the D5CSRA with different indoor units (the table titles on these pages cover 18K 4-way cassette and 9K AE console). Each block is one outdoor-air temperature (DB) row, from -22°F (-30°C) up to 122°F (50°C). Each row gives three values per indoor-air condition: TC (total cooling capacity), S/T (sensible-to-total heat ratio) and PI (power input). Values are grouped by indoor wet-bulb (ID WB) and indoor dry-bulb (ID DB) columns, and each table is labelled with one airflow in CFM.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5CSRA outdoor units with indoor units: 4-way cassette, AE console, and similar cooling tables on pages 64 to 72

How to fix how to read the d5csra cooling performance matrices: step by step

  1. Find the table for the indoor unit type and capacity size (9K, 12K, 18K, 24K and so on) by its title.
  2. Note the airflow in CFM printed above the block and pick the matching airflow.
  3. Select the outdoor DB row that matches the outdoor air temperature on site.
  4. Read across to the indoor WB and DB column that matches the room conditions.
  5. Read TC for capacity, S/T for the sensible share, and PI for the electrical input at those conditions.
  6. Use the note in the table heading for any capacity table that continues onto the next page.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Mini-Split codes

Source: D5CSRA Product Data, p. 64-72. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.