Viessmann Heat Pump: Table 64 – 9K Heating, High Static Slim Duct: how to read the heating data
Table 64 – 9K Heating, High Static Slim Duct: how to read the heating data on a Viessmann heat pump: Heating performance grid for the 9K D5CSRA with the high static slim duct indoor unit. Airflow blocks shown are 206, 247, 318 and 371 CFM. Outdoor dry bulb rows run from -22°F to 64.4°F. Capacity (BTU/hr) is in the first five columns and power input (kW) in the last five, at indoor dry bulb temperatures of 60.8, 68, 70, 71.6 and 75.2°F. The -22°F row is blank ('/').
Applies to: D5CSRA 9K heating, High Static Slim Duct indoor unit
How to fix table 64 – 9k heating, high static slim duct: how to read the heating data: step by step
- Select the airflow block that matches the indoor unit airflow in CFM.
- Find the outdoor dry bulb row for the actual outdoor temperature.
- Read total heating capacity (BTU/hr) from the first five columns for the indoor temperature.
- Read power input (kW) from the last five columns in the same row.
- If the airflow is between blocks, use the nearest tabulated block and record that choice.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Source: D5CSRA Product Data, p. 172–173. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.