Viessmann Heat Pump: Table 63 – 18K Heating, Low Static Slim Duct: how to read the heating data
Table 63 – 18K Heating, Low Static Slim Duct: how to read the heating data on a Viessmann heat pump: Heating performance grid for the 18K D5CSRA with the low static slim duct indoor unit. Airflow blocks shown are 441, 500, 559 and 600 CFM. Outdoor dry bulb rows run from -22°F to 64.4°F. Capacity (BTU/hr) is in the first five columns and power input (kW) in the last five, at indoor dry bulb temperatures of 60.8, 68, 70, 71.6 and 75.2°F. The -22°F row is blank ('/').
Applies to: D5CSRA 18K heating, Low Static Slim Duct indoor unit
How to fix table 63 – 18k heating, low static slim duct: how to read the heating data: step by step
- Select the airflow block that matches the indoor unit airflow in CFM.
- Find the outdoor dry bulb row for the actual outdoor temperature.
- Read total heating capacity (BTU/hr) from the first five columns for the indoor temperature.
- Read power input (kW) from the last five columns in the same row.
- Use the nearest tabulated airflow block if the actual airflow is between blocks, and record that choice.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Source: D5CSRA Product Data, p. 170–171. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.