Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: Table 62 – 12K Heating, Low Static Slim Duct: how to read the heating data

Updated · by Aurora Star Tech Inc.

Table 62 – 12K Heating, Low Static Slim Duct: how to read the heating data on a Viessmann heat pump: Heating performance grid for the 12K D5CSRA with the low static slim duct indoor unit. Each airflow block (176, 265, 324 and 400 CFM) lists outdoor dry bulb temperatures from -22°F to 64.4°F. For each outdoor temperature, the first five columns give total heating capacity (BTU/hr) and the next five give power input (kW), at indoor dry bulb temperatures of 60.8, 68, 70, 71.6 and 75.2°F. The -22°F row has no values printed (shown as '/').

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5CSRA 12K heating, Low Static Slim Duct indoor unit

How to fix table 62 – 12k heating, low static slim duct: how to read the heating data: step by step

  1. Find the airflow block that matches the indoor unit's airflow in CFM.
  2. Find the outdoor dry bulb row for the actual outdoor temperature.
  3. Read total capacity (BTU/hr) from the first five columns, under the matching indoor dry bulb column.
  4. Read power input (kW) from the last five columns, same row and indoor column.
  5. If the actual airflow falls between two blocks, do not guess; use the manual's nearest tabulated value and note it on the job record.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Source: D5CSRA Product Data, p. 168–171. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977