Viessmann Heat Pump: Servicing the strip heater and replacement parts

Updated · by Aurora Star Tech Inc.

Servicing the strip heater and replacement parts on a Viessmann heat pump: The heater is fed from a separate branch circuit, so it must be isolated on its own.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Optional electric strip heat accessory

How to fix servicing the strip heater and replacement parts: step by step

  1. Disconnect all power to the heat pump and the heater before servicing.
  2. Refer to the wiring diagram on the inside of the heater control box cover.
  3. Make sure all components are repositioned and reconnected per the wiring diagram.
  4. Use only replacement parts identical to the originals or approved by Viessmann.
  5. Quote the job number on the heater label when requesting parts or technical support.
  6. Do not fit non-authorised components or make non-approved modifications.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056

Source: Vitocal 100-WA installation, service and operating instructions, p. 39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.