Viessmann Heat Pump: Rooms are too cold
Rooms are too cold on a Viessmann heat pump: Heating is not keeping rooms warm enough.
Applies to: Vitocal 100-AW AM2V
Common causes of rooms are too cold
- Heat pump is switched off.
- Controller settings were changed or are incorrect.
- DHW heating is in progress.
- Display shows a Warning or Fault.
How to fix rooms are too cold: step by step
- Switch on the power switch.
- Switch on the main switch if fitted outside the mechanical room.
- Check the house fuse in the electrical switchboard.
- Check work program, heating curve, room temperature, time and the space heating time program.
- Enable additional electric heating for space heating if needed.
- Wait until DHW heating finishes, or reduce hot water draw or temporarily lower the normal DHW temperature.
- Read out and confirm the Warning or Fault.
- If needed, contact an Authorised Service Centre.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 67. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.