Viessmann Heat Pump: Room temperature sensor location and wiring
Room temperature sensor location and wiring on a Viessmann heat pump: Place the room sensor in the main living room on an internal wall, away from heat sources and draughts.
Applies to: Vitocal 100-AW AM2V indoor unit
How to fix room temperature sensor location and wiring: step by step
- Mount on an internal wall in the main living room.
- Keep at least 5 ft (1.5 m) from the floor.
- Keep away from windows, doors, radiators and heat sources such as direct sun, a fireplace or a TV.
- Use two-wire cable up to 150 ft (50 m) long, 22 AWG (0.34 mm2).
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Source: Vitocal 100-AW AM2V installation manual, p. 27. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.